Last edited by Zoloran
Tuesday, August 4, 2020 | History

5 edition of Optical Coherence Tomography and Coherence Techniques II found in the catalog.

Optical Coherence Tomography and Coherence Techniques II

12-16 June 2005, Munich, Germany (Progress in Biomedical Optics and Imaging,)

by European Physical Society.

  • 359 Want to read
  • 36 Currently reading

Published by SPIE-International Society for Optical Engine .
Written in English


The Physical Object
FormatPaperback
Number of Pages1
ID Numbers
Open LibraryOL11393664M
ISBN 100819458635
ISBN 109780819458636

  Optical Coherence Tomography System. A home-built and previously described swept source OCT system 28 was used in this study. Briefly, a 36 kHz short cavity laser source with a polygon-based tuneable filter and wavelength centered at nm had a sweep range of nm and an average output power of 40 by: 8. Three-dimensional ophthalmic optical coherence tomography with a refraction correction algorithm. in Optical Coherence Tomography and Coherence Techniques: SPIE, ed. by W. Drexler, International Society for Optics and photonics, Munich, Germany, vol. () Google Scholar.

Optical Coherence Tomography in Glaucoma features updated information on technical applications of OCT in glaucoma, reviews recently published literature and provides clinical cases based on Cirrus and Spectralis OCT platforms. In addition, newer techniques like event and trend analyses for progression, macular ganglion cell analysis, and OCT. Lasers and Current Optical Techniques in Biology aims to provide an overview of light sources, together with an extensive and authoritative description of the optical techniques in bio-medicine. This book is designed to give biomedical researchers a strong feel for the capability of physical approaches, promote new interdisciplinary interests.

This book introduces the latest optical coherence tomography (OCT) imaging and computerized automatic image analysis techniques, and their applications in the diagnosis and treatment of retinal diseases. Discussing the basic principles and the clinical applications of OCT imaging, OCT image preprocessing, as well as the automatic detection and. Measurements of the posterior structures of the human eye in vivo by partial coherence interferometry using diffractive optics Angela Baumgartner, Beate M ller, Christoph K. Hitzenberger, Wolfgang Drexler, Adolf F. Fercher (in Coherence Domain Optical Methods in Biomedical Science and Clinical Applications, V. V. Tuchin, H. Podbielska, B. Ovryn, editors, .


Share this book
You might also like
La celosa de si misma =

La celosa de si misma =

Reduced condensing pressure operation in industrial ammonia refrigeration systems

Reduced condensing pressure operation in industrial ammonia refrigeration systems

Shrewsbury - a future for the past?.

Shrewsbury - a future for the past?.

Nottingham hand-book

Nottingham hand-book

Brevard County, Fl Map

Brevard County, Fl Map

Alternative dispute resolution

Alternative dispute resolution

truth about Robin Hood

truth about Robin Hood

CFD analysis and design optimization using parallel computers

CFD analysis and design optimization using parallel computers

The Photons Journey CE Test Kit

The Photons Journey CE Test Kit

Improving social security in Canada.

Improving social security in Canada.

Bible

Bible

Twelve color plates

Twelve color plates

Bookkeeping and accounting practice

Bookkeeping and accounting practice

history of Protestantism

history of Protestantism

Optical Coherence Tomography and Coherence Techniques II by European Physical Society. Download PDF EPUB FB2

Optical Coherence Tomography gives a broad treatment of the subject which will include 1)the optics, science, and physics needed to understand the technology 2) a description of applications with a critical look at how the technology will successfully address actual clinical need, and 3) a discussion of delivery of OCT to the patient, FDA approval and comparisons with available /5(9).

Introduction to full-field optical coherence microscopy Arnaud Dubois Theory of imaging and coherence effects in full-field optical coherence microscopy Anton Grebenyuk and Vladimir Ryabukho Spatio-temporal coherence effects in full-field optical coherence tomography Ibrahim Abdulhalim Cross-talk in full-field optical coherence tomography Boris Karamata, Marcel.

Optical Coherence Tomography and Coherence Techniques II: Editors: W. Drexler: Place of Publication: Munich: Publisher: SPIE: Pages: Number of pages: ISBN (Print) Publication status: Published - 13 Jun Event: European Conferences on Biomedical Optics, ECBO - Munich, Germany Duration: 12 Jun → 16 Jun.

"These proceedings are from the Optical Coherence Tomography and Coherence Techniques Conference, held in June as part of the European Conferences on Biomedical Optics in Munich"--Page xi.

Reproduction Notes: Electronic reproduction. Bellingham, Wash.: SPIE--the International Society for Optical Engineering, Ovarian cancer is the deadliest gynecologic cancer, but can be addressed with early detection. We investigate optical coherence tomography for imaging ovarian cancer, finding that tissue changes can be detected through quantitative analysis.

Optical Coherence Tomography Angiography of the Eye is designed to be the definitive text on this cutting-edge technology for the retina specialist and. Optical Coherence Tomography gives a broad treatment of the subject which will include 1)the optics, science, and physics needed to understand the technology 2) a description of applications with a critical look at how the technology will successfully address actual clinical need, and 3) a discussion of delivery of OCT to the patient, FDA approval and comparisons with available.

The detection of early stages of caries is still one of the major challenges in preservative dentistry. Since it is known from polarized light microscopy (PLM) that intrinsic enamel birefringence is affected by demineralization, polarization-sensitive optical coherence tomography (PSOCT) could facilitate the noninvasive detection and assessment of early carious lesions.

Proc. SPIEOptical Coherence Tomography and Coherence Domain Optical Methods in Biomedicine XXIV, (19 March ); doi: / A novel speckle reduction technique based on soft thresholding of wavelet coefficients using interval type II fuzzy system was developed for reducing speckle noise in.

Get this from a library. Optical coherence tomography in glaucoma: a practical guide. [Ahmet Akman; Atilla Bayer; Kouros Nouri-Mahdavi;] -- This book focuses on the practical aspects of Optical Coherence Tomography (OCT) in glaucoma diagnostics offering important theoretical information along with many original cases.

OCT is a. Laser beam welding significantly outperforms conventional joining techniques in terms of flexibility and productivity. The process benefits, in particular, from the highly focused energy and thus f. However, techniques enabling a fast, contactless, non-invasive, and high-resolution imaging of subsurface features at a level of only a few microns are still scarce.

One technology fulfilling all of these requirements is optical coherence tomography (OCT). OCT is a purely optical, non-destructive, non-invasive, and contactless high resolution Cited by: 8. This book will serve as a reference for ophthalmologists and optometrists worldwide with a special interest in OCT imaging providing essential guidance on the application of OCT in glaucoma.\/span>\"@ en\/a> ; \u00A0\u00A0\u00A0\n schema:description\/a> \" Part I: Optical Coherence Tomography in Glaucoma, Basics -- Chapter 1:Optical Coherence.

We have combined Fourier-domain optical coherence tomography (OCT) with a closed-loop Adaptive Optics (AO) system. The AO-OCT instrument has been used for in vivo retinal imaging. High-lateral resolution of our AO-OCT system allows visualization of the microscopic retinal structures not accessible by standard OCT : Robert J.

Zawadzki, Stacey Choi, Sophie Laut, John S. Werner, Steven M. Jones, Scot S. Olivier, Ming. Optical coherence tomography (OCT) is a non-contact, non-invasive imaging technique used to acquire high-resolution cross-sectional images of the ocular structures. INTRODUCTION During the last 20 years, optical coherence tomography (OCT) has evolved into a powerful technique for imaging of transparent and translucent structures.

OCT is an attractive noninvasive, non-touch imaging technique for obtaining high-resolution images. OCT is based on low-coherence interferometry (LCI) and achieves micron-scale cross-sectional. Introduction. Based on the principle of low coherence interferometry, OCT is a relatively recent imaging modality that was proposed in the early s.

1 It measures depth-resolved reflections of near-infrared light to create cross-sectional images of tissue with micrometer resolution. 2 The capability of OCT to noninvasively image tissue at the Cited by: Optical coherence tomography (OCT) is commonly used in clinical settings for the diagnosis and management of glaucoma.

15 Doppler OCT has been used to obtain precise measurements of total retinal blood flow calculated from the Doppler frequency shift of backscattered light. 15 While appropriate for large vessels around the disc, Doppler OCT is Cited by: This book focuses on the practical aspects of Optical Coherence Tomography (OCT) in glaucoma diagnostics offering important theoretical information along with many original cases.

OCT is a non-invasive imaging technique that acquires high-resolution images of the ocular structures. Optical coherence tomography (OCT) has recently attracted a lot of interest in the pharmaceutical manufacturing industry as a fast, contactless and non-destructive modality for quantifying thin film coatings on pharmaceutical dosage forms, which cannot be resolved easily with other techniques.Abstract.

Optical coherence tomography (OCT) is a medical imaging modality that opens up new opportunities for imaging in breast cancer. It provides two- and three-dimensional micro-scale images of tissue structure from bulk tissue, in vivo or freshly excised without labeling or staining, is capable of video-rate acquisition speeds, and is compatible with compact imaging probes.Manually-operated compressional optical coherence elastography with effective aperiodic averaging: demonstrations for corneal and cartilaginous tissues A A Sovetsky, A L Matveyev, L A Matveev, D V Shabanov and V Y ZaitsevCited by: